Power Factor Correction

BMR power factor controllers provide accurate and reliable reactive power compensation for capacitor banks, reactor banks, and hybrid systems. The portfolio includes FCR and GCR controllers for standard compensation cabinets as well as CTU thyristor modules for dynamic power factor correction.

Thanks to the proprietary APFR (Average Power Factor Regulation) technology, BMR controllers reduce switching operations, eliminate overcompensation, improve efficiency, and extend the lifetime of compensation equipment.

Controllers

This image for Image Layouts addon

FCR05 & FCR07

Reactive power controller with 6 or 8 relay outputs for LV and HV systems with symetrical load in panel design 96x96mm, RS485.

This image for Image Layouts addon

FCR05DL & FCR07DL

Reactive power controller with 6 and 8 relay outputs for LV and HV systems with symetrical load in DIN rail design, RS485.

This image for Image Layouts addon

FCR06 & FCR12

Reactive power controll for standard, dynamic and hybrid PFC with 6 or 12 outputs for LV and HV systems with symetrical load in panel design 144x144mm, RS485.

This image for Image Layouts addon

GCR06 & GCR12

advanced reactive power controller for standard, dynamic and hybrid PFC with 6 and 12 regulated outputs in LV and HV systems with symetric load in panel design 144x144mm, RS485 communication interface.
This image for Image Layouts addon

FCR06T & FCR12T

reactive power controll for standard, dynamic and hybrid PFC with 6 and 12 regulated outputs in LV and HV systems with non-symetrical load in panel design 144x144mm, RS485 communication interface.
This image for Image Layouts addon

GCR06E & GCR12E

advanced power controller for standard, dynamic, and hybrid PFC systems with 6/12 regulated outputs for symmetric and asymmetric LV/HV loads, 144 × 144 mm panel design, Ethernet and RS485 communication.

This image for Image Layouts addon

ICR12

impulse controrller for regulation of PFC cabinets by reading impulses from static 4-quadrant energy counters. Controller is in design for panel installation in size of 144x144mm.

Thyristor Switching Modules

This image for Image Layouts addon

CTU02

thyristor switching modules for switching of three-phase LV power capacitors in PFC systems with symetrical load and periodical or fast load changes.
This image for Image Layouts addon

CTU03

thyristor switching modules for switching of single-phase LV power capacitors in PFC systems with symetrical load and periodical or fast load changes.