Class A PQ analyser PLA44 DL

Power quality analysers is designed according to the norm IEC 61000-4-30 cl. A ed. 3 for continuous measurement of electrical parameters in LV and MV systems for further power quality investigation. The PLA44 DL is built with a powerful RISC processor that provides sufficient processing capabilities for real-time measurement and calculation of all parameters and values.

Continuous sampling of the voltage and current inputs at 40 kHz, guarantees the highest accuracy. The PLA44 DL is the instrument for power quality monitoring according to EN 50160 of the incoming energy supply side as well as on the consumer side in order to find and analyse the root cause of network problems.

PLA44
fa fa-cogs
  • U and I accuracy 0.1
  • sampling frequency 40 kHz
  • communication interfaces Ethernet, USB, RS485
  • communication protocols Modbus RTU, Modbus TCP, SNTP, SMTP, FTP, HTTP, MTP, MQTT
  • RS485 Modbus gateway
  • 2 x digital I/O
  • 3 voltage and 3 current inputs
far fa-chart-bar
  • measuring according IEC 61000-4-30 ed.3 cl. A
  • harmonics, interharmonics EN 61000-4-7 up to 64th
  • flicker EN 61000-4-15
  • suitable for PQ reports EN 50160
  • transient detection > 25 μs
  • events detection > 10 ms
  • avg, max, min recorded value
  • external temperature sensor
fas fa-layer-group
  • on board logging Flash memory 1GB
  • WWW-server and email notification
  • DIN rail mounting design
  • PMS SW for configuration, monitoring and evaluation
  • MQTT support
  • PQDIF export
  • EN50160, IEEE519-2014, PGC, PDC reports

Function

Voltage and current signals are digitalized by high class A/D converter and computing with RISC microprocessor. Effective values are computed continuously in 200 ms (10 periods) windows. Independently on this computing is for events detection each 10 ms counted effective value of U and I. Another absolutely independent part is transient detection that are directly detected from samples of digitalized U and I.

IEC 61000-4-30 ed.3 cl. A

PQ analyzer PLA44 DL measures according the standard IEC 61000-4-30 ed. 3 class A. Such type of analyzers are used in applications where there is necessary precise measurement for power quality evaluation according norms EN 50160, EN 61000-4-7 and EN 61000-4-15. If two devices of class A measures the same signal of voltage and current, measurement results at the same moment have to be  same with defined measurement uncertainty.

Events

Events are unexpected signal changes with duration from 10ms up to days. In some installations these events can cause material damages and economical lost. Norm EN 50160 defines limits of events and its quantity that can appear in electrical grid during a year. PQA PLA44 DL evaluates following type of events DIP, INT, SWELL, RVC and I_MAX.

Transients

Voltage transients are short commutation, impulse or oscillatory events in electrical grid. Their source can be inductive load switching, power factor correction instruments, atmospheric events, protection instruments action or malfunction of switching elements in the grid.

PLA44 DL analyser detects two types of transients. Absolute transients and differential transients.

MQTT

Integration of MQTT protocol into power quality analyser PLA44 DL allows implementation of instrument to any SW. Measured data are divided into several topics in which user can chose which one want to receive. Measured data are transferred in file format JSON.

Image

Software

Software PMS - Power Monitor System offers possibility for essential configuration of PLA44 DL. More over it is a tool to define recording template, alarms, and defined events and transients limits for PQ evaluation. Another part of PMS SW is used for PQ evaluation and report generation.

Measured parameters

 
parameter L1 L2 L3 L4 L1-2 L2-3 L3-1 ∑L1-L3 ∑L1-L4 Max Min Avg Range Display Accuracy
phase voltage tečkatečkatečkatečkatečkatečka 10...600 V 1 V...1 MV 0.1%
line-line voltage tečkatečkatečkatečkatečkatečka 18...1000 V 0...1 MV 0.1%
system frequency tečka        tečkatečkatečka 40...70 Hz 40...70 Hz 10 mHz
current tečkatečkatečkatečkatečkatečka 0.001...8.5 A 1 mA...1 MA 0.1%
cosφtečkatečkatečkatečka 0.01L...0.01C 0.01L...0.01C 1 %
power factor tečkatečkatečkatečkatečka 0.01L...0.01C 0.01L...0.01C 1 %
THDU L-N tečkatečkatečkatečkatečkatečka 0...99.9% 0...999% 1 %
THDU L-L     tečkatečkatečka  tečkatečkatečka 0...99.9% 0...999% 1 %
THDI tečkatečkatečka      tečkatečkatečka 0...99.9% 0...999% 1 %
U harmonicics tečkatečkatečka          0...99.9% 0...999% class 1
group of U interharmonics tečkatečkatečka          0...99.9% 0...999% class 1
group of U harmonics tečkatečkatečka          0...99.9% 0...999% class 1
P harmonics tečkatečkatečka          0...99.9% 0...999% class 1
Q harmonics tečkatečkatečka          0...99.9% 0...999% class 1
I harmonics tečkatečkatečka          0...99.9% 0...999% class 1
group of I interharmonics tečkatečkatečka          0...99.9% 0...999% class 1
group of I harmonics tečkatečkatečka          0...99.9% 0...999% class 1
short-term flicker tečkatečkatečka      tečkatečkatečka 0.4...10.0 0.4...10.0 class A
long-term flicker tečkatečkatečka      tečkatečkatečka 0.4...10.0 0.4...10.0 class A
under-voltage tečkatečkatečka tečkatečkatečka  tečkatečkatečka 0...100% 0...100% 0.2%
over-voltage tečkatečkatečka tečkatečkatečka  tečkatečkatečka 0...100% 0...100% 0.2%
asymmetry of voltage          tečkatečkatečka 0...100% 0...100% 0.15%
N wire voltage          tečkatečkatečka 10...600 V 0...1 MV 0.2%
K-factor tečkatečkatečka            
asymmetry of current          tečkatečkatečka   0.5%
PQ transients tečkatečkatečka            25 μs
PQ events tečkatečkatečka            10 ms
ripple control tečkatečkatečka tečkatečkatečka  tečkatečkatečka   
active power tečkatečkatečka    tečka tečka tečka 0...15.3 kW 0...999 GW 0.2%
reactive power tečkatečkatečka    tečka tečka tečka 0...15.3 kvar 0...999 Gvar 0.2%
aparent power tečkatečkatečka    tečka tečka tečka 0...15.3 kVA 0...999 GVA 0.2%
distortion power tečkatečkatečka    tečka tečka tečka   0.2%
active energy +/- tečkatečkatečka    tečka     0...999 GWh 0...999 GWh class 0.5S
reactive L energy +/- tečkatečkatečka    tečka     0...999 Gvarh 0...999 Gvarh class 1
reactive C energy +/- tečkatečkatečka    tečka     0...999 Gvarh 0...999 Gvarh class 1
temperature          tečkatečkatečka   1°C

Technical features

ParameterValue
auxiliary supply voltage85 ... 250 VAC/DC (±10%) or 24 ... 60 VAC/DC (±10%)
self consumption< 8 VA
time uncertinity< 1 s a day
number of I/O2
VT and CT ratio1...750 000
sampling rate40 kHz
event detection> 10 ms
transient detection> 25 μs
logger memory1 GB flash
displayLCD
external temperature sensorNTC 10 kΩ / 25°C
communication interfacesRS485 / LAN / USB
communication protocolsModbus RTU, Modbus TCP, SNTP, SMTP, HTTP, FTP, MTP, MQTT
ambient temperature-25°C ... +70°C
dimensions6 DIN modules
weight400 g
protection degreeIP20 rear side
related standardsEN 61000-4-30 class A / EN 61000-4-7 / EN 61000-4-15 class A / EN 61557-12